Usefulness of the EpiSkin reconstructed human epidermis model within Integrated Approaches

Usefulness of the EpiSkin™ reconstructed human epidermis model within Integrated Approaches on Testing and Assessment (IATA) for skin corrosion and irritation

 

Predictive capacity of the EpiSkin™ model was evaluated on 87 chemicals using the Bottom-Up and the Top-Down testing approaches recommended within Integrated Approach on Testing and Assessment for the identification of both skin irritation and corrosion hazards. Classified (UN GHS Cat. 1 and Cat. 2) chemicals were identified with a very high sensitivity (≥94%) and the non-classified (UN GHS Cat. 3 and No Cat.) chemicals with an appropriate specificity (70%). Very high sensitivities were obtained for the identification of Cat. 1 chemicals (≥98%), very high specificities for non-Cat. 1 chemicals (93%), and accuracies of −95% for the identification of skin corrosives vs. non-corrosives by both approaches. Overall accuracies of 72% were found for predicting the single (sub)categories: non-classified, Cat. 2, Subcat. 1B/1C and Subcat. 1A. Results indicated the testing strategies to be more predictive than the individual assays on a conservative safety approach. Finally, no extreme misclassifications (no under-prediction of in vivo Subcat. 1A as non-Cat. 1, and no over-prediction of non-classified chemical as Subcat. 1A) occur. These findings, independently of the approach used, confirm the usefulness of the EpiSkin™ in vitro model for a safe prediction of the skin irritant and corrosive hazards of chemicals.